Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Knee Surg Sports Traumatol Arthrosc ; 32(1): 37-46, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38226696

RESUMO

PURPOSE: Shoulder stiffness (SS) is a condition characterised by active and passive restricted glenohumeral range of motion, which can occur spontaneously in an idiopathic manner or be associated with a known underlying aetiology. Several treatment options are available and currently no consensus has been obtained on which treatment algorithm represents the best choice for the patient. Herein we present the results of a national consensus on the treatment of primary SS. METHODS: The project followed the modified Delphi consensus process, involving a steering, a rating and a peer-review group. Sixteen questions were generated and subsequently answered by the steering group after a thorough literature search. A rating group composed by professionals specialised in the diagnosis and treatment of shoulder pathologies rated the question-answer sets according to the scientific evidence and their clinical experience. RESULTS: Recommendations were rated with an average of 8.4 points out of maximum 9 points. None of the 16 answers received a rating of less than 8 and all the answers were considered as appropriate. The majority of responses were assessed as Grade A, signifying a substantial availability of scientific evidence to guide treatment and support recommendations encompassing diagnostics, physiotherapy, electrophysical agents, oral and injective medical therapies, as well as surgical interventions for primary SS. CONCLUSIONS: A consensus regarding the conservative and surgical treatment of primary SS could be achieved at a national level. This consensus sets basis for evidence-based clinical practice in the management of primary SS and can serve as a model for similar initiatives and adaptable guidelines in other European countries and potentially on a global scale. LEVEL OF EVIDENCE: Level I.


Assuntos
Artropatias , Ombro , Humanos , Consenso , Modalidades de Fisioterapia , Extremidade Superior
2.
Bioengineering (Basel) ; 10(12)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38136000

RESUMO

The purpose of this study was to investigate how lateralization shoulder angle (LSA) and distalization shoulder angle (DSA) are related to clinical and kinematic outcomes after reverse total shoulder arthroplasty. Thirty-three patients were evaluated at least six months postoperatively. The Single Assessment Numeric Evaluation (SANE), Constant Murley Score (CMS), Simple Shoulder Test (SST), and Visual Analogue Scale (VAS) were used. Shoulder kinematics was evaluated with a stereophotogrammetric system. LSA and DSA inter-rater reliability was analysed through the interclass correlation coefficient (ICC). Stepwise forward linear regression analysis was conducted between LSA and DSA with clinical scales and kinematic measures, between which a correlation analysis was conducted. The inter-rater reliability for LSA (mean ICC = 0.93) and DSA (mean ICC = 0.97) results were good to excellent. Greater LSA values were associated with higher peaks of internal rotation (p = 0.012, R2 = 0.188) and range of motion (ROM) (p = 0.037, R2 = 0.133). SANE (p = 0.009), CMS (p = 0.031), and SST (0.026) were positively correlated to external rotation, while VAS (p = 0.020) was negatively related. Abduction peaks were positively related to CMS (p = 0.011) and SANE (p = 0.037), as well as abduction ROM (SANE, p = 0.031; CMS, p = 0.014).

3.
Bioengineering (Basel) ; 10(11)2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38002429

RESUMO

Few studies have evaluated the effectiveness of shoulder rehabilitation in virtual environments. The objective of this study was to investigate the performance of a custom virtual reality application (VR app) with a stereophotogrammetric system considered the gold standard. A custom VR app was designed considering the recommended rehabilitation exercises following arthroscopic rotator cuff repair. Following the setting of the play space, the user's arm length, and height, five healthy volunteers performed four levels of rehabilitative exercises. Results for the first and second rounds of flexion and abduction displayed low total mean absolute error values and low numbers of unmet conditions. In internal and external rotation, the number of times conditions were not met was slightly higher; this was attributed to a lack of isolated shoulder movement. Data is promising, and volunteers were able to reach goal conditions more often than not. Despite positive results, more literature comparing VR applications with gold-standard clinical parameters is necessary. Nevertheless, results contribute to a body of literature that continues to encourage the application of VR to shoulder rehabilitation programs.

4.
BMC Musculoskelet Disord ; 24(1): 859, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37919702

RESUMO

BACKGROUND: Virtual Reality (VR) systems have been increasingly used across several medical fields. A crucial preliminary step for developing optimized VR-based applications for rehabilitation purposes is identifying potential interventions to meet the requirements necessary to satisfy end-users' needs. This study aims to assess the acceptability, usability, and appropriateness of a VR physical therapy program executed with Oculus Quest 2 by expert physiotherapists of shoulder musculoskeletal rehabilitation. METHODS: Eleven physiotherapists were enrolled to test a VR program for shoulder musculoskeletal rehabilitation. At the end of each session, physiotherapists completed three questionnaires about the acceptability, usability, and appropriateness of the VR system and application, investigating aspects such as wearability, safety, stability, ease of control, comfort, size, utility, playability, and use mode. RESULTS: The acceptability questionnaire revealed that all the physiotherapists found the VR system easy to wear and control, very confident, and safe. The usability questionnaire showed that most physiotherapists (73%) found the VR application entertaining, although only 45% said the system could be used independently by patients without the support of a therapist. Many physiotherapists found the use of the VR application appropriate for patients with rotator cuff tears treated conservatively (63.6%) or surgically (54.5%), for patients with shoulder osteoarthritis treated conservatively (72.7%), for patients with shoulder osteoarthritis after surgical treatment (63.6%). 91% of physiotherapists think it would be best for patients to use the VR system under the supervision of a therapist and not independently in a home setting. CONCLUSIONS: The use of VR in orthopaedic rehabilitation is encouraging, although further efforts are needed to increase the independent use of patients without the supervision of a physiotherapist. Moreover, future studies should strive to ensure the clinical effectiveness of VR rehabilitation in reaching therapeutic goal settings.


Assuntos
Osteoartrite , Realidade Virtual , Humanos , Ombro , Extremidade Superior , Modalidades de Fisioterapia
5.
Sensors (Basel) ; 23(15)2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37571723

RESUMO

Monitoring shoulder kinematics, including the scapular segment, is of great relevance in the orthopaedic field. Among wearable systems, magneto-inertial measurement units (M-IMUs) represent a valid alternative for applications in unstructured environments. The aim of this systematic literature review is to report and describe the existing methods to estimate 3D scapular movements through wearable systems integrating M-IMUs. A comprehensive search of PubMed, IEEE Xplore, and Web of Science was performed, and results were included up to May 2023. A total of 14 articles was included. The results showed high heterogeneity among studies regarding calibration procedures, tasks executed, and the population. Two different techniques were described, i.e., with the x-axis aligned with the cranial edge of the scapular spine or positioned on the flat surface of the acromion with the x-axis perpendicular to the scapular spine. Sensor placement affected the scapular motion and, also, the kinematic output. Further studies should be conducted to establish a universal protocol that reduces the variability among studies. Establishing a protocol that can be carried out without difficulty or pain by patients with shoulder musculoskeletal disorders could be of great clinical relevance for patients and clinicians to monitor 3D scapular kinematics in unstructured settings or during common clinical practice.


Assuntos
Articulação do Ombro , Dispositivos Eletrônicos Vestíveis , Humanos , Fenômenos Biomecânicos , Escápula , Ombro , Amplitude de Movimento Articular
6.
Artigo em Inglês | MEDLINE | ID: mdl-36231336

RESUMO

Shoulder dysfunctions represent the third musculoskeletal disorder by frequency. However, monitoring the movement of the shoulder is particularly challenging due to the complexity of the joint kinematics. The 3D kinematic analysis with optical motion capture systems (OMCs) makes it possible to overcome clinical tests' shortcomings and obtain objective data on the characteristics and quality of movement. This systematic review aims to retrieve the current knowledge about using OMCs for 3D shoulder kinematic analysis in patients with musculoskeletal shoulder disorders and their corresponding clinical relevance. The Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines were used to improve the reporting of the review. Studies employing OMCs for 3D kinematic analysis in patients with musculoskeletal shoulder disorders were retrieved. Eleven articles were considered eligible for this study. OMCs can be considered a powerful tool in orthopedic clinical research. The high costs and organizing complexities of experimental setups are likely outweighed by the impact of these systems in guiding clinical practice and patient follow-up. However, additional high-quality studies on using OMCs in clinical practice are required, with standardized protocols and methodologies to make comparing clinical trials easier.


Assuntos
Articulação do Ombro , Ombro , Fenômenos Biomecânicos , Humanos , Movimento (Física) , Movimento , Amplitude de Movimento Articular , Extremidade Superior
7.
Sensors (Basel) ; 22(15)2022 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35898015

RESUMO

Virtual reality (VR) systems are becoming increasingly attractive as joint kinematics monitoring systems during rehabilitation. This study aimed to evaluate the accuracy of the Oculus Quest 2 in measuring translational and rotational displacements. As the Oculus Quest 2 was chosen for future applications in shoulder rehabilitation, the translation range (minimum: ~200 mm, maximum: ~700 mm) corresponded to the forearm length of the 5th percentile female and the upper limb length of the 95th percentile male. The controller was moved on two structures designed to allow different translational displacements and rotations in the range 0-180°, to cover the range of motion of the upper limb. The controller measures were compared with those of a Qualisys optical capture system. The results showed a mean absolute error of 13.52 ± 6.57 mm at a distance of 500 mm from the head-mounted display along the x-direction. The maximum mean absolute error for rotational displacements was found to be 1.11 ± 0.37° for a rotation of 40° around the z-axis. Oculus Quest 2 is a promising VR tool for monitoring shoulder kinematics during rehabilitation. The inside-out movement tracking makes Oculus Quest 2 a viable alternative to traditional motion analysis systems.


Assuntos
Ombro , Realidade Virtual , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Movimento , Extremidade Superior
8.
Sensors (Basel) ; 21(17)2021 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-34502652

RESUMO

Monitoring scapular movements is of relevance in the contexts of rehabilitation and clinical research. Among many technologies, wearable systems instrumented by strain sensors are emerging in these applications. An open challenge for the design of these systems is the optimal positioning of the sensing elements, since their response is related to the strain of the underlying substrates. This study aimed to provide a method to analyze the human skin strain of the scapular region. Experiments were conducted on five healthy volunteers to assess the skin strain during upper limb movements in the frontal, sagittal, and scapular planes at different degrees of elevation. A 6 × 5 grid of passive markers was placed posteriorly to cover the entire anatomic region of interest. Results showed that the maximum strain values, in percentage, were 28.26%, and 52.95%, 60.12% and 60.87%, 40.89%, and 48.20%, for elevation up to 90° and maximum elevation in the frontal, sagittal, and scapular planes, respectively. In all cases, the maximum extension is referred to the pair of markers placed horizontally near the axillary fold. Accordingly, this study suggests interesting insights for designing and positioning textile-based strain sensors in wearable systems for scapular movements monitoring.


Assuntos
Articulação do Ombro , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Humanos , Movimento , Amplitude de Movimento Articular , Extremidade Superior
9.
BMC Musculoskelet Disord ; 22(1): 749, 2021 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-34465332

RESUMO

BACKGROUND: Rotator cuff retear (RCR) is one of the main postoperative drawbacks. RCR can be considered a multifactorial issue, which causes are related either to biological than biomechanical factors. The aim of this study was to define the incidence of RCR after surgical treatment at different time points and to identify the main factors influencing the postoperative rotator cuff (RC) healing. METHODS: A systematic review and meta-analysis were performed following the PRISMA guidelines. A comprehensive search of the literature was carried out in July 2020, using PubMed and Cochrane Library databases. Only level 1 and 2 clinical evidence studies were included. Studies were included if patients with preoperative repairable full-thickness RC tears were treated surgically, and if studies reported postoperative RCR confirmed by imaging diagnostic. The association between timing of retear and follow-up time points were investigated using an inverse-variance method of pooling data. A subgroup meta-analysis was performed using the DerSimonian and Laird method for the estimation of the between-study variance, i.e., τ2. The association between retear rate after surgery and patients' age, preoperative tear size, fatty infiltration, postoperative rehabilitation protocol, surgical techniques, and RC repairs was determined by expressing the effect measure in terms of odds ratio (OR) with 95% confidence interval (CI). The Mantel-Haenszel method with 95% CIs was used. RESULTS: Thirty-one articles were included in this study. The percentage of RCR after surgery was 15% at 3 months follow-up, 21% at 3-6 months follow-up, 16% at 6-12 months follow-up, 21% at 12-24 months follow-up, 16% at follow-up longer than 24 months. The main factors influencing RC healing are both patient-related (i.e., age, larger tear size, fatty infiltration) and not patient-related (i.e., postoperative rehabilitation protocol, surgical techniques, and procedures). CONCLUSIONS: Postoperative RC healing is influenced by patient-related and non-patient-related factors. Further high-level clinical studies are needed to provide highly relevant clinical results.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Artroplastia , Artroscopia , Humanos , Imageamento por Ressonância Magnética , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/epidemiologia , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento
11.
BMC Musculoskelet Disord ; 22(1): 637, 2021 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-34303366

RESUMO

BACKGROUND: The purpose of this systematic review and meta-analysis is to compare the conservative and accelerated rehabilitation protocols in patients who underwent arthroscopic rotator cuff repair in terms of clinical outcomes and range of motions at 3, 6, 12, and 24-month follow-up. METHODS: According to PRISMA guidelines, a systematic review of the literature was performed. For each included article, the following data has been extracted: authors, year, study design, level of evidence, demographic characteristics, follow-up, clinical outcomes, range of motions, and retear events. A meta-analysis was performed to compare accelerated versus conservative rehabilitation protocols after arthroscopic rotator cuff repair. The retear rate, postoperative Constant-Murley score and range of motions at 3, 6, 12, and 24 months of follow-up were the outcomes measured. RESULTS: The search strategy yielded 16 level I-II clinical studies. A total of 1424 patients, with 732 patients and 692 in the accelerated and conservative group, were included. The average age (mean ± standard deviation) was 56.1 ± 8.7 and 56.6 ± 9 in the accelerated and conservative group. The mean follow-up was 12.5 months, ranging from 2 to 24 months. The meta-analysis showed no statistically significant differences in terms of retear rate between the groups (P = 0.29). The superiority of the accelerated group was demonstrated in terms of external rotation (P < 0.05) at 3-month follow-up; in terms of forward elevation, external rotation, abduction (P < 0.05), but not in terms of Constant-Murley score at 6-month follow-up; in terms of forward elevation (P < 0.05) at 12-month follow-up. No significant differences between the two group were highlighted at 24-month follow-up. CONCLUSIONS: No statistically significant differences in the retear rate among the accelerated and conservative group have been demonstrated. On the other hand, statistically and clinically significant differences were found in terms of external rotation at 3 and 6 months of follow-up in favour of the accelerated group. However, no differences between the two groups were detected at 24 months follow-up.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Artroscopia , Humanos , Amplitude de Movimento Articular , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento
12.
J Pers Med ; 11(4)2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33915689

RESUMO

Rotator cuff (RC) disease is a common musculoskeletal disorder of the shoulder entailing pain, with reduced functionality and quality of life. The main objective of this study was to present a perspective of the current scientific evidence about personalized, predictive, participatory, precision, and preventive approaches in the management of RC diseases. The personalized, predictive, participatory, precision and preventive (P5) medicine model is an interdisciplinary and multidisciplinary approach that will provide researchers and clinicians with a comprehensive patrimony of knowledge in the management of RC diseases. The ability to define genetic predispositions in conjunction with the evaluation of lifestyle and environmental factors may boost the tailoring of diagnosis and therapy in patients suffering from RC diseases.

13.
BMC Musculoskelet Disord ; 22(1): 50, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33419401

RESUMO

BACKGROUND: This study aims to compare conservative versus surgical management for patients with full-thickness RC tear in terms of clinical and structural outcomes at 1 and 2 years of follow-up. METHODS: A comprehensive search of CENTRAL, MEDLINE, EMBASE, CINAHL, Google Scholar and reference lists of retrieved articles was performed since the inception of each database until August 2020. According to the Cochrane Handbook for Systematic Reviews of Interventions, two independent authors screened all suitable studies for the inclusion, extracted data and assessed risk of bias. Only randomised controlled trials comparing conservative and surgical management of full-thickness RC tear in adults were included. The primary outcome measure was the effectiveness of each treatment in terms of Constant-Murley score (CMS) and VAS pain score at different time points. The secondary outcome was the integrity of the repaired tendon evaluated on postoperative MRI at different time points. The GRADE guidelines were used to assess the critical appraisal status and quality of evidence. RESULTS: A total of six articles met the inclusion criteria. The average value of CMS score at 12 months of follow-up was 77.6 ± 14.4 in the surgery group and 72.8 ± 16.5 in the conservative group, without statistically significant differences between the groups. Similar results were demonstrated at 24 months of follow-up. The mean of VAS pain score at 12 months of follow-up was 1.4 ± 1.6 in the surgery group and 2.4 ± 1.9 in the conservative group. Quantitative synthesis showed better results in favour of the surgical group in terms of VAS pain score one year after surgery (- 1.08, 95% CI - 1.58 to - 0.58; P < 0.001). CONCLUSIONS: At a 2-year follow-up, shoulder function evaluated in terms of CMS was not significantly improved. Further high-quality level-I randomised controlled trials at longer term follow-up are needed to evaluate whether surgical and conservative treatment provide comparable long-term results.


Assuntos
Lesões do Manguito Rotador , Adulto , Humanos , Artroscopia , Ensaios Clínicos Controlados Aleatórios como Assunto , Manguito Rotador , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Ombro , Dor de Ombro , Resultado do Tratamento
15.
BMC Musculoskelet Disord ; 21(1): 687, 2020 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-33069229

RESUMO

BACKGROUND: This study aims (1) to estimate the yearly number of Achilles tendon (AT) surgeries in Italy from 2001 to 2015 based on official hospitalization records; (2) to investigate the eventual presence of geographical variation in equity in access to AT surgery between three macroregions of Italy (North, Center and South); (3) to perform statistical projections of the number of AT procedure volumes and rates based on these data. METHODS: We analysed the National Hospital Discharge records (SDO) maintained at the Italian Ministry of Health for a 15-year period, from 2001 through 2015. These data are anonymous and include the patient's age (evaluated in the class of age), sex, census region, the region of hospitalization, length of the hospitalization, public or private reimbursement and diagnosis. RESULTS: During the 15-year study period, 118,652 AT repair were performed in Italy, whose peak of incidence was in 2010. More than half of AT repairs was performed in the North of Italy (52.1%), while 27.2% was performed in the South of Italy and 20.6% Center of Italy. The projection model predicted a slight growth of 2.65% in 2025 in comparison with 2015. CONCLUSION: The current study provides detailed information about the national population-weighted incidence of AT surgery, distribution and projection. The peak of average age was 35-45 year. The majority of AT procedures was performed in the North of Italy. The projection model predicts a slight growth of AT surgery by 2025. Furthermore, this 15-year nationwide registry study shows that the age of incidence of AT injuries shifted from 30 to 40 to 35-45 years compared to the available literature. The higher prevalence of AT surgery was found in men during the working age. Moreover, a low rate of procedures in pediatric and elder age classes was observed.


Assuntos
Tendão do Calcâneo , Tendão do Calcâneo/cirurgia , Adulto , Idoso , Criança , Hospitalização , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros
17.
Artigo em Inglês | MEDLINE | ID: mdl-32344746

RESUMO

Background: This study intends to summarize the causes, clinical examination, and treatments of scapular dyskinesis (SD) and to briefly investigate whether alteration can be managed by a precision rehabilitation protocol planned on the basis of features derived from clinical tests. Methods: We performed a comprehensive search of PubMed, Cochrane, CINAHL and EMBASE databases using various combinations of the keywords "Rotator cuff", "Scapula", "Scapular Dyskinesis", "Shoulder", "Biomechanics" and "Arthroscopy". Results: SD incidence is growing in patients with shoulder pathologies, even if it is not a specific injury or directly related to a particular injury. SD can be caused by multiple factors or can be the trigger of shoulder-degenerative pathologies. In both cases, SD results in a protracted scapula with the arm at rest or in motion. Conclusions: A clinical evaluation of altered shoulder kinematics is still complicated. Limitations in observing scapular motion are mainly related to the anatomical position and function of the scapula itself and the absence of a tool for quantitative SD clinical assessment. High-quality clinical trials are needed to establish whether there is a possible correlation between SD patterns and the specific findings of shoulder pathologies with altered scapular kinematics.


Assuntos
Discinesias , Escápula , Articulação do Ombro , Fenômenos Biomecânicos , Humanos , Amplitude de Movimento Articular , Escápula/fisiopatologia , Ombro , Articulação do Ombro/fisiopatologia
18.
Artigo em Inglês | MEDLINE | ID: mdl-32326198

RESUMO

BACKGROUND: The objective of the present study was to compare the efficacy between supervised and unsupervised rehabilitation after rotator-cuff (RC) repair in terms of clinical outcomes, visual-analog-scale (VAS) score, range of motion (ROM), and risk of retear. MATERIAL: a comprehensive search of Pubmed, CINAHL, Cochrane, EMBASE, Ovid, and Google Scholar databases through a combination of the following keywords with logical Boolean operators: "informed", "uninformed", "unsupervised", "supervised", "rehabilitation", "physical therapy", "physical therapies", "postoperative period", "physical-therapy techniques", "physical-therapy technique", "exercise", "exercise therapy", "rotator cuff", "rotator-cuff tear", and "rotator-cuff repair". For each article included in the study, the following data were extracted: authors, year, study design, sample size and demographic features, RC tear characteristics, clinical outcomes, ROM, VAS score, retear rate, and time of follow-up. Meta-analysis was performed in terms of VAS score. RESULTS: Four randomized control trials with 132 patients were included. One study demonstrated significant improvement in VAS, active ROM, and the activity of the muscle's motor units at stop and during maximal effort in supervised patients. Another one showed lower retear rates in the supervised group. The remaining two randomized controlled trials did not reveal any significant differences between supervised and unsupervised rehabilitation in terms of clinical outcomes. Moreover, higher costs were described for supervised rehabilitation. The VAS was not significantly different in the two groups (9.9 compared with 8.25, p = 0.23). CONCLUSIONS: although several publications address the problem of RC lacerations, there is a paucity of evidence in the literature regarding the effectiveness of supervised and unsupervised rehabilitation protocols. This systematic review and meta-analysis showed no significant differences between the two types of rehabilitation in terms of VAS scores, while outlining the pros and cons of each protocol.


Assuntos
Modalidades de Fisioterapia , Lesões do Manguito Rotador , Artroscopia , Análise Custo-Benefício , Humanos , Amplitude de Movimento Articular , Manguito Rotador , Lesões do Manguito Rotador/reabilitação , Resultado do Tratamento
19.
Int Orthop ; 44(5): 893-903, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32157371

RESUMO

PURPOSE: To describe the main features of the rehabilitation protocols for RC disease based on the phases of tendon healing and to investigate about the use of wearable devices as monitoring systems. METHODS: We performed a comprehensive search of PubMed, Medline, Cochrane, CINAHL, and EMBASE databases using various combination of the keywords "rotator cuff," "rotator cuff tear," "rehabilitation protocol," "accelerated," "conservative," "stiffness," "exercises," and "wearable devices." All articles concerning precision orthopaedic rehabilitation therapy in rotator cuff disease were retrieved. RESULTS: To date, rehabilitation protocols are not comparable due to wide heterogeneity of RC diseases. Wearable technologies are becoming a revolutionary tool for movement and posture monitoring. CONCLUSION: Rehabilitation protocols for RC disease should be tailored on the basis of the different phases of tendon healing. Wearable devices hold the promise to offer a new outlook for long-term follow-up during the postoperative period providing information to the clinician about patient's status.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Artroscopia , Humanos , Modalidades de Fisioterapia , Amplitude de Movimento Articular , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Ombro , Resultado do Tratamento
20.
Sensors (Basel) ; 20(2)2020 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-31963696

RESUMO

Musculoskeletal disorders are the most common form of occupational ill-health. Neck pain is one of the most prevalent musculoskeletal disorders experienced by computer workers. Wrong postural habits and non-compliance of the workstation to ergonomics guidelines are the leading causes of neck pain. These factors may also alter respiratory functions. Health and safety interventions can reduce neck pain and, more generally, the symptoms of musculoskeletal disorders and reduce the consequent economic burden. In this work, a multi-parametric wearable system based on two fiber Bragg grating sensors is proposed for monitoring neck movements and breathing activity of computer workers. The sensing elements were positioned on the neck, in the frontal and sagittal planes, to monitor: (i) flexion-extension and axial rotation repetitions, and (ii) respiratory frequency. In this pilot study, five volunteers were enrolled and performed five repetitions of both flexion-extension and axial rotation, and ten breaths of both quite breathing and tachypnea. Results showed the good performances of the proposed system in monitoring the aforementioned parameters when compared to optical reference systems. The wearable system is able to well-match the trend in time of the neck movements (both flexion-extension and axial rotation) and to estimate mean and breath-by-breath respiratory frequency values with percentage errors ≤6.09% and ≤1.90%, during quiet breathing and tachypnea, respectively.


Assuntos
Monitorização Fisiológica/métodos , Pescoço/fisiologia , Taxa Respiratória/fisiologia , Dispositivos Eletrônicos Vestíveis , Adulto , Computadores , Ergonomia , Feminino , Humanos , Masculino , Monitorização Fisiológica/instrumentação , Projetos Piloto , Processamento de Sinais Assistido por Computador , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA